StorageTek™L20Tape LibraryService Manual96041Revision: P
viii Revision P 96041Sun Confidential - Internal OnlyFiguresFigure 1-1. External Fans . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Drives without Load Handles1-74 Revision P 96041Sun Confidential - Internal OnlyFigure 1-15. Newer Model Drives Terminating Power Jumpers 1. Quantum S
96041 Revision P 1-75Sun Confidential - Internal OnlyDrives without Load HandlesFigure 1-16. Quantum Certance Drive Terminating Power Jumpers 1. Turn
Drives without Load Handles1-76 Revision P 96041Sun Confidential - Internal Only5. Using a Torx driver, attach the four screws on the bottom of the dr
96041 Revision P 1-77Sun Confidential - Internal OnlyDrives without Load HandlesNote: Three cables must be connected to the drive. The cables are list
Drives without Load Handles1-78 Revision P 96041Sun Confidential - Internal Only
96041 Revision P 2-1Sun Confidential - Internal Only2Library HVD-to-LVD ConversionThe LLC card supports both high voltage differential (HVD) and low v
2-2 Revision P 96041Sun Confidential - Internal OnlyFigure 2-1. LLC Card Jumper Locations (L201_334)1. J17 Terminating power• Left two columns jumpere
96041 Revision P 2-3Sun Confidential - Internal OnlyFigure 2-2. Library SCSI Option Jumpers (L201_341)1. High Voltage Differential (HVD) operation: SC
2-4 Revision P 96041Sun Confidential - Internal OnlyThis page intentionally left blank.
96041 Revision P 3-1Sun Confidential - Internal Only3FirmwareFirmware is factory-installed on all new libraries. The firmware resides within a Flash P
96041 Revision P ixSun Confidential - Internal OnlyTablesTable 1-1. LTO Drive Backward Readability . . . . . . . . . . . . . . . . . . . . . . . . .
PC to LLC Card Procedure3-2 Revision P 96041Sun Confidential - Internal Only7. Unzip the file, leaving the unzipped files in this folder.Note: Use a Z
96041 Revision P 3-3Sun Confidential - Internal OnlyLibrary Status ToolThe status window for the transfer appears.CAUTION:Equipment Damage: Do not att
Library Status Tool3-4 Revision P 96041Sun Confidential - Internal Only3. Use Internet Explorer (5.0 or later) or Netscape (4.5 or later) as the Web b
96041 Revision P 3-5Sun Confidential - Internal OnlyLibrary Status Tool• To save a report to your hard drive from the Library Status Tool, type the fu
Library Status Tool3-6 Revision P 96041Sun Confidential - Internal OnlyLibrary Status Tool ExamplesThe Library Status Tool display is dynamic, allowin
96041 Revision P 3-7Sun Confidential - Internal OnlyLibrary Status ToolGenerating ReportsAn illustration of the Library Status Tool Reports screen is
Library Status Tool3-8 Revision P 96041Sun Confidential - Internal OnlyFigure 3-2. Report: Library Status Tool (L201_508)
96041 Revision P 3-9Sun Confidential - Internal OnlyLibrary Status ToolLoading CodeBefore loading code to the library, see “Java Policy Permissions” o
Library Status Tool3-10 Revision P 96041Sun Confidential - Internal OnlyCAUTION:Equipment Damage: Do not attempt to perform any operations on the libr
96041 Revision P 3-11Sun Confidential - Internal OnlyLibrary Status ToolRebooting the LibraryTo reboot the library:1. Select Reboot from the Library S
Tablesx Revision P 96041Sun Confidential - Internal Only
Library Status Tool3-12 Revision P 96041Sun Confidential - Internal OnlySNMPSun StorageTek’s L-series libraries support Version 1 of the simple networ
96041 Revision P Index-1 Sun Confidential - Internal OnlyIndexAalert messages in manual, xiarm safety, xviiiautomated mode operationsmonitoring the li
IndexIndex-2 Revision P 96041 Sun Confidential - Internal OnlyFibre Channel router card, 1-5Fibre Channel router, external, 1-10LLC card, 1-21LLC card
96041 Revision P Index-3 Sun Confidential - Internal OnlyIndexMmanual, related publications, xiiimonitoring the library using the Library Status tool,
IndexIndex-4 Revision P 96041 Sun Confidential - Internal OnlyVviewing, Library Status tool, 3-3Wwarningdescription of, xieye hazard from laser, xxlib
SUN™THE NETWORK IS THE COMPUTER ©2006 Sun Microsystems, Inc. All rights reserved. Sun, Sun Microsystems, and the Sun logo are trademarks or registered
96041 Revision P xiSun Confidential - Internal OnlyPrefaceThis manual describes how to remove and replace field replaceable units (FRUs) in the L20 ta
xii Revision P 96041Sun Confidential - Internal Only ConventionsTypographical conventions highlight special words, phrases, and actions in this publi
96041 Revision P xiiiSun Confidential - Internal Only Related PublicationsYou can find additional information in the following publications.Library D
xiv Revision P 96041Sun Confidential - Internal Only Additional InformationSun Microsystems, Inc. (Sun) offers several methods for you to obtain addi
96041 Revision P xvSun Confidential - Internal OnlyPartners SiteThe StorageTek Partners site is a Web site for partners with a StorageTek Partner Agre
xvi Revision P 96041Sun Confidential - Internal OnlyThis page intentionally left blank.
96041 Revision P xviiSun Confidential - Internal OnlyPersonal SafetyThe following pages describe common practices concerning electrical safety, ergono
xviii Revision P 96041Sun Confidential - Internal OnlyLifting TechniquesLifting, regardless of how much or how little, can create serious back stress.
96041 Revision P xixSun Confidential - Internal Only Rack Safety and PrecautionsWARNING:Possible personal injury:• Lifting hazard: The library (with
xx Revision P 96041Sun Confidential - Internal Only Fiber-optic SafetyWARNING:Eye hazard. Never look directly into a fiber-optic cable, a fiber-optic
96041 Revision P xxiSun Confidential - Internal OnlyProduct PrecautionsThe following pages describe common practices concerning fiber optics and elect
xxii Revision P 96041Sun Confidential - Internal OnlyFiber-optic Cable HandlingObserve these precautions when you handle fiber-optic cables:• Do not c
96041 Revision P xxiiiSun Confidential - Internal Only• Reinstall all equipment covers and close all equipment doors after you have completed the work
xxiv Revision P 96041Sun Confidential - Internal Onlya. If you are working on components from a small piece of equipment, attach the free end of the c
96041 Revision P 1-1Sun Confidential - Internal Only1FRU ReplacementThis chapter describes procedures for removing and replacing the field replaceable
External Fans1-2 Revision P 96041Sun Confidential - Internal Only External FansThere are two external fans, one behind each drive.Figure 1-1. Externa
96041 Revision P 1-3Sun Confidential - Internal OnlyExternal FansRemoval1. Follow the procedures in “Repair Setup” on page 1-1. 2. Pull out the four,
L20Tape LibraryService Manual
External Fans1-4 Revision P 96041Sun Confidential - Internal OnlyReplacement1. Check the fan case and make sure that the arrow on the case points to t
96041 Revision P 1-5Sun Confidential - Internal OnlyFibre Channel Router Card Fibre Channel Router CardFigure 1-2. Fibre Router Card (L201_203)
Fibre Channel Router Card1-6 Revision P 96041Sun Confidential - Internal OnlyRemoval1. Follow the procedures in “Repair Setup” on page 1-1. CAUTION:Co
96041 Revision P 1-7Sun Confidential - Internal OnlyFibre Channel Router Card7. Pull back the module to release the card tab from the slot.1. Tab8. Re
Fibre Channel Router Card1-8 Revision P 96041Sun Confidential - Internal OnlyReplacement1. LLC card2. SCSI Y cable J3 connector1. Remove the card from
96041 Revision P 1-9Sun Confidential - Internal OnlyFibre Channel Router Card7. Insert the card tab through the slot.1. Tab2. Slot8. At the rear of th
External Fibre Channel Router1-10 Revision P 96041Sun Confidential - Internal Only External Fibre Channel RouterFigure 1-3. External Fibre Channel Ro
96041 Revision P 1-11Sun Confidential - Internal OnlyExternal Fibre Channel RouterRemoval1. Follow the procedures in “Repair Setup” on page 1-1. 2. Re
External Fibre Channel Router1-12 Revision P 96041Sun Confidential - Internal OnlyReplacement1. Remove two mounting brackets from the old router and i
96041 Revision P 1-13Sun Confidential - Internal OnlyLibrary Power Supply Library Power SupplyFigure 1-4. Library Power Supply (L201_204)L201_204
ii Revision P 96041Sun Confidential - Internal OnlyCopyright 2006 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, California 95054, U.S.A. A
Library Power Supply1-14 Revision P 96041Sun Confidential - Internal OnlyRemoval1. Follow the procedures in “Repair Setup” on page 1-1. 2. Make sure t
96041 Revision P 1-15Sun Confidential - Internal OnlyLibrary Power Supply5. Open the cable lock near the P1 cable connector.6. Disconnect P1. (This co
Library Power Supply1-16 Revision P 96041Sun Confidential - Internal Only10. Remove the wing nut from the power supply tensioner.Notes:1. The 5/16-in.
96041 Revision P 1-17Sun Confidential - Internal OnlyLibrary Power Supply12. Remove the 5/16-in. nut and the bracket.1. 5/16-in. nut
Library Power Supply1-18 Revision P 96041Sun Confidential - Internal OnlyReplacement1. Remove the power supply from its static-protected shipping bag.
96041 Revision P 1-19Sun Confidential - Internal OnlyLibrary Power Supply4. Insert the tensioner bracket.5. Loosely attach the wing nut.1. Wing nut6.
Library Power Supply1-20 Revision P 96041Sun Confidential - Internal Only8. Connect P1.9. Open the cable lock and insert the cable from the P1 connect
96041 Revision P 1-21Sun Confidential - Internal OnlyLLC Card LLC CardFigure 1-5. LLC Card (L201_202)L201_202
LLC Card1-22 Revision P 96041Sun Confidential - Internal OnlyRemovalCAUTION:Possible component damage: Before beginning this procedure, you must remov
96041 Revision P 1-23Sun Confidential - Internal OnlyLLC Card1. P42 connector6. Remove the remaining cables except the Operator Panel connector at J29
96041 Revision P iiiSun Confidential - Internal OnlySummary of ChangesEC Date Edition Description111628 March 2001 First Initial release111661 July 20
LLC Card1-24 Revision P 96041Sun Confidential - Internal Only11. Remove the 11 T10 screws that attach the LLC card to the mounting plate or to standof
96041 Revision P 1-25Sun Confidential - Internal OnlyLLC CardFigure 1-6. LLC Card Jumper Locations (L201_334)1. J17 Terminating power• Left two column
LLC Card1-26 Revision P 96041Sun Confidential - Internal OnlyFigure 1-7. LLC Card Connections (L201_228)1. J29 operator panel12. J27 CSE port2. J824 (
96041 Revision P 1-27Sun Confidential - Internal OnlyLLC CardReplacement1. Remove the LLC card from its static-protected shipping bag.2. Insert the LL
LLC Card1-28 Revision P 96041Sun Confidential - Internal Only8. Add a tie wrap to secure the P42 cable to the floor of the library.1. Connector P429.
96041 Revision P 1-29Sun Confidential - Internal OnlyLLC Card10. Tighten the four T15 screws 1. Screws11. Reinstall the LLC card fan (See “LLC Card Fa
LLC Card Fan1-30 Revision P 96041Sun Confidential - Internal Only LLC Card FanNote: This fan must always be removed before removing the LLC card.Figu
96041 Revision P 1-31Sun Confidential - Internal OnlyLLC Card FanRemoval1. Follow the procedures in “Repair Setup” on page 1-1.2. Unlock and pull open
LLC Card Fan1-32 Revision P 96041Sun Confidential - Internal OnlyReplacement1. Check the fan case and make sure that the arrow on the case points to t
96041 Revision P 1-33Sun Confidential - Internal OnlyLLC Card SCSI Cable Assembly LLC Card SCSI Cable AssemblyFigure 1-9. LLC Card SCSI Cable Assembl
Summary of Changesiv Revision P 96041Sun Confidential - Internal OnlyThis page intentionally left blank.
LLC Card SCSI Cable Assembly1-34 Revision P 96041Sun Confidential - Internal OnlyRemoval1. Follow the procedures in “Repair Setup” on page 1-1.2. Use
96041 Revision P 1-35Sun Confidential - Internal OnlyLLC Card SCSI Cable AssemblyReplacementCAUTION:SCSI interface problem: Make sure that you connect
Operator Panel1-36 Revision P 96041Sun Confidential - Internal Only Operator PanelFigure 1-10. Operator Panel (L201_205)L201_205
96041 Revision P 1-37Sun Confidential - Internal OnlyOperator PanelRemoval1. Follow the procedures in “Repair Setup” on page 1-1.CAUTION:ESD damage: M
Operator Panel1-38 Revision P 96041Sun Confidential - Internal Only6. From under the library drawer, locate the single T15 screw underneath the drawer
96041 Revision P 1-39Sun Confidential - Internal OnlyOperator Panel9. Remove the three T15 screws from the front of the operator panel.1. Operator pan
Operator Panel1-40 Revision P 96041Sun Confidential - Internal OnlyReplacement1. Make sure that you have followed the ESD precautions in “ESD Precauti
96041 Revision P 1-41Sun Confidential - Internal OnlyOperator Panel5. Align the metal bracket to fit within the alignment slots.1. Metal bracket2. Ali
Operator Panel1-42 Revision P 96041Sun Confidential - Internal Only9. Pivot the front cover back to its original position.10. Tighten the single T15 s
96041 Revision P 1-43Sun Confidential - Internal OnlyOperator Panel12. Insert the plastic cover and tip the top of the cover toward the front of the l
96041 Revision P vSun Confidential - Internal OnlyContentsSummary of Changes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Picker1-44 Revision P 96041Sun Confidential - Internal Only PickerFigure 1-11. Picker (L201_201)L201_201
96041 Revision P 1-45Sun Confidential - Internal OnlyPickerRemoval1. Follow the procedures in “Repair Setup” on page 1-1.CAUTION:ESD damage: Make sure
Picker1-46 Revision P 96041Sun Confidential - Internal Only6. Carefully lift the picker straight up to remove it from its track.1. Release point for p
96041 Revision P 1-47Sun Confidential - Internal OnlyPicker10. Disconnect the picker cable connector (P601) at the circuit card.1. P6012. Picker11. Re
Picker1-48 Revision P 96041Sun Confidential - Internal OnlyReplacementCAUTION:ESD damage: Make sure that you have followed the ESD precautions in “ESD
96041 Revision P 1-49Sun Confidential - Internal OnlyPicker7. Turn over the picker.CAUTION:Picker damage: Make sure that you move the picker at the po
Picker1-50 Revision P 96041Sun Confidential - Internal Only10. From under the library, attach the picker plate with the two T10 screws.1. Screws (2) 1
96041 Revision P 1-51Sun Confidential - Internal OnlyDrive SCSI Cable Assembly Drive SCSI Cable AssemblyFigure 1-12. Drive SCSI Cable Assembly Replac
Drive SCSI Cable Assembly1-52 Revision P 96041Sun Confidential - Internal OnlyRemoval1. Follow the procedures in “Repair Setup” on page 1-1.CAUTION:ES
96041 Revision P 1-53Sun Confidential - Internal OnlyDrive SCSI Cable AssemblyReplacement4. Use a 3/16 inch driver to remove the four jack screws from
Contentsvi Revision P 96041Sun Confidential - Internal Only1: FRU Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Drive SCSI Cable Assembly1-54 Revision P 96041Sun Confidential - Internal Only2. Connect the SCSI connector to the drive.1. ConnectorCAUTION:Possible
96041 Revision P 1-55Sun Confidential - Internal OnlyDrive and Cartridge Compatibility Drive and Cartridge CompatibilityThe following caution and tab
Drive and Cartridge Compatibility1-56 Revision P 96041Sun Confidential - Internal OnlyTable 1-2. Compatible Drives and Interfaces Drive NameSustained
96041 Revision P 1-57Sun Confidential - Internal OnlyDLT Drives with Load Handles DLT Drives with Load HandlesSee “Drive and Cartridge Compatibility”
DLT Drives with Load Handles1-58 Revision P 96041Sun Confidential - Internal OnlyFigure 1-13. DLT Drive with Load Handle (L201_321)1. DLT drive label2
96041 Revision P 1-59Sun Confidential - Internal OnlyDLT Drives with Load HandlesRemovalCAUTION:Component damage: Do not touch components on the drive
DLT Drives with Load Handles1-60 Revision P 96041Sun Confidential - Internal Only8. Turn the drive and tray to gain access to the TTI cable cover and
96041 Revision P 1-61Sun Confidential - Internal OnlyDLT Drives with Load Handles12. Note the position of the terminating power jumper (shown in Figur
DLT Drives with Load Handles1-62 Revision P 96041Sun Confidential - Internal OnlyReplacement481. Place the drive on a flat, sturdy work surface.2. For
96041 Revision P 1-63Sun Confidential - Internal OnlyDLT Drives with Load HandlesCAUTION:Drive load failure: Make sure that the crank handle is inside
96041 Revision P viiSun Confidential - Internal OnlyContentsSDLT 320 Bezel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DLT Drives with Load Handles1-64 Revision P 96041Sun Confidential - Internal Only8. Plug in the TTI cable.9. Replace the cable cover and screw.1. TTI
96041 Revision P 1-65Sun Confidential - Internal OnlyDLT Drives with Load Handles1. Knob2. Range of motion3. Latch arm (shown disengaged)2. Slide the
Drives without Load Handles1-66 Revision P 96041Sun Confidential - Internal Only Drives without Load HandlesSee “Drive and Cartridge Compatibility” o
96041 Revision P 1-67Sun Confidential - Internal OnlyDrives without Load HandlesRemovalCAUTION:Component damage: Do not touch components on the drive
Drives without Load Handles1-68 Revision P 96041Sun Confidential - Internal OnlyDrives with a Cartridge BezelWhen removing following drives, make sure
96041 Revision P 1-69Sun Confidential - Internal OnlyDrives without Load HandlesTo replace the bezel:IBM LTO BezelThe IBM bezel is attached to the fro
Drives without Load Handles1-70 Revision P 96041Sun Confidential - Internal OnlyQuantum (Certance) LTO BezelTo remove the bezel:To replace the bezel:S
96041 Revision P 1-71Sun Confidential - Internal OnlyDrives without Load HandlesTo replace the bezel:SDLT 600 BezelTo remove the bezel:1. Tabs2. Targe
Drives without Load Handles1-72 Revision P 96041Sun Confidential - Internal OnlyTo replace the bezel:2. Rotate the bezel away from the drive faceplate
96041 Revision P 1-73Sun Confidential - Internal OnlyDrives without Load HandlesReplacementFigure 1-14. Older Model Drives Terminating Power Jumpers 1